• phone
    phone
  • mail
    phone
    banner
    banner
    banner
    banner

    Hazard warning lamp

    Baseefa Approved Hazard Warning Lamp

    The BASEEFA Approved Hazard Warning Lamp – HL-95 is powered by an air-depolarised primary cell battery, which has an exceptionally high capacity from a relatively small, lightweight package size. A single battery, used in the flashing light output mode, provides continuous duration for up to 1500 hours, or two months. In static mode where the lamp is continuously lit, the duration will be up to 500 hours. Operation of the lamp and selection of flashing or static mode is made from a single three position toggle switch mounted on the outside of the lamp. A further extension to battery duration can be achieved by selecting ‘daylight cut-out mode’ via the internally mounted selection switch. If the lamp is being used outdoors a light dependant resistor will detect when darkness falls and accordingly activate the lamp. Equally, when light levels increase, it automatically switches off, conserving battery energy. It is estimated that a lamp set to flashing and in daylight cut-out mode could operate for up to six months from a single battery.

    The HL-95 has two lenses positioned ‘back to back’ with the light output from these lenses being greater than 2cd. Light is provided by a pair of ‘everlasting’ light emitting diodes. The use of such solid-state devices allows the lamp to be sited in zone 0, 1 or 2 hazardous areas. The light emitting diodes are coloured amber and are positioned behind a transparent plastic lens. The lens is protected from damage by a Stainless-Steel guard fitted directly to the impact resistant, static dissipative polypropylene lamp body.

    • Qty down-arrow down-arrow
    • Approved for safe use in Zones 0, 1 or 2
    • Flashing or static output selectable
    • Operation in flashing mode up to 2 months
    • Daylight cut-out mode selectable
    • Ultra-bright L.E.D. light source
    • 180° bi-directional lens arrangement
    • Highlighting obstacles in the hazardous area
    • Effective demarcation of hazardous area zones

    To Fit Battery: Remove locking screw and separate the lamp front from rear. Fit battery into lamp front and attach connector, ensure the connector is firmly attached to both terminals. Re-assemble two halves of lamp and locking screw, ensure wires are not trapped.

    Operation: External switch provides output selection as follows: on static – off – on flashing. Internal switch on the LED circuit board allows selection of daylight ‘cut-out mode’, automatically turning the lamp off in daylight, extending the battery life. The flash rate may increase if the lamp is operated near radio frequency emissions in the range 100MHz to 115MHz.

    Request a Quote