Elastic Straps
Used to temporarily hold ceramic pad heating elements in place whilst they are correctly
positioned and spaced prior to fixing in place with tie wire or banding.
Banding Tape
For bands of more than 4 heating elements, Cooperheat recommends that steel banding
and banding clips are used to ensure the heaters remain in full contact with the pipe. For
temperatures in excess of 650°C we recommend using stainless steel banding and clips.
Please note that mild steel banding should not be used on Chrome Molybdenum post weld
heat treatments.
Banding Clips
Mild and stainless steel clips for fastening mild and stainless steel banding.
Banding Tools For Metal Banding Tape
For tightening, cutting off and clipping mild and stainless steel banding.
Recorder Spares
Stock reference & description for EH Series Chino:
- 542-230 0-1200°C 180mm Fan fold chart ET-201
- 542-230/1 0-1200°C 180mm Fan fold chart EH-05035
- 542-234 Ink pad case complete with ink pads
- 542-231 Ink (12 Colours)
Single Pole Contactors
Replacement single pole contactors and contacts for 0-65V and 0-85V output heat treatment modules and units.
Double Pole Contactors
Replacement single pole contactors and contacts for 32.5-0-32.5V and 42.5-0-42.5V output,
heat treatment modules and units.
Circuit Breakers
Replacement mains circuit breaker for heat treatment modules and units.
Thermocouple Attachment Unit Spares
Replacement parts for Thermocouple Attachment Units (TAUs).
Thermocouple Wire
Type K nickel chrome/nickel aluminium thermocouple wire, insulated with high temperature glass braid. Recommended maximum temperature 800°C. A consumable item, which is used to convert the thermal energy at the hot junction of the thermocouple to an electrical mV signal which can then be used by temperature control and recording instruments to accurately control and record the temperature of the item being heat treated.
Conforms to: BS EN 60584-1 : 1996 Part 4
BS EN 60584-2 : 1993 Class 1 & ANSI-MC96
The thermocouple wire is attached directly to the work piece using the ‘thermocouple attachment unit’ stock reference: 41756 (115V unit) or 41757 (230V unit).
Thermocouple Connectors
Type ‘K’ plug and socket thermocouple connectors. We offer two types of thermocouple plugs, type 516-111 being the standard type normally used with compensating cable. Whereas type 516-115 ‘quick connection’ plugs are ideally suited for use with thermocouple wire where regular connections are required.
Tubular, Stainless Steel Sheathed Thermocouples
Commonly used for temperature measurement in furnaces and ovens.
High Temperature Putty
A small portion of the soft putty is fixed over the hot junction of the thermocouple, which is attached to the item being heat treated. Once the putty dries, after 20 minutes, it hardens to protect the hot junction and helps avoid possible short circuit of the thermocouple wires which would result in temperature control and recording errors.
Digital Thermocouple Calibration Unit
The hand held thermocouple calibration unit is an accurate measurement and millivolt source instrument, which is used to calibrate thermocouple instrumentation.It can measure or simulate 8 different thermocouple types and be used as a millivolt source. The instrument comes complete with the carrying bag, user’s manual and a calibration certificate.
True RMS Digital Clamp Meter
The digital clamp meter is an AC/DC multifunction clamp meter capable of measuring a.c or d.c voltage to 600V, a.c current up to 400A, input impedance for DCV: 10MΩ and temperature up to 1000°C using a type ‘K’ thermocouple. Jaw capacity 30mm. LCD Backlight, auto and manual ranging, diode test and continuity buzzer, data hold, flashlight, auto power off, low battery indication: ≤ 3.6V, input protection. Standard accessories are test leads, point contact temperature probe, carrying bag and user manual.
60A In-Line Connectors
Spare connectors for repair of splitters and heating elements.
300A In-Line Connectors
Spare connectors for repair of triple cable sets and splitters.
300A Panel Mounted Connectors
Spare panel mounted connector sockets for repair of heat treatment modules and units. Supplied complete with fibre washer and lock nut.
Energy Regulator & Aluminium Knob
Energy regulator for 110V use, aluminium knob and replacement dial for use with 110V energy regulator.
110V 6 Way Control Plug & Socket
Spare in line plug and panel mounted socket, for repair of 110V control cables and control inputs and outputs.
110V Control Plugs & Sockets
Spare in-line XLR plugs and panel-mounted sockets for repair of 110V control cables and control inputs and outputs.
Electrical Fittings – Various
All wiring and cable accessories as used in our equipment are available for purchase. The more common parts detailed below.
Fuses – Various
Various fuses and holders available as spares for our equipment. Common parts detailed below.
110V supply plugs and sockets
Spare in-line plugs and panel mounted sockets for repair of 110V supply cables and supply outputs.
Flexible Insulated Preheat Magnets
Pair of powerful limpet magnets with cross bar used to quickly clamp Flexible Insulated Preheaters (FIPs) to the workpiece being preheated.
Surface Combustion Unit Spare Plaque & Gasket Set
Replacement parts for repair of Surface Combustion Units (SCU).
Soft Iron Tie Wire
For heating element bands of less than 4 heating elements, soft iron wire is adequate to fix the heating elements and insulation around the workpiece.